Project

General

Profile

Bug #10019

Some images from Nikon P7000 are unusably ping-violet

Added by Martin Kyral almost 5 years ago. Updated over 4 years ago.

Status:
Fixed
Priority:
Low
Assignee:
-
Category:
Darkroom
Start date:
07/17/2014
Due date:
% Done:

100%

Estimated time:
0.20 h
Affected Version:
1.4.2
System:
Fedora/RHEL
bitness:
64-bit
hardware architecture:
amd64/x86

Description

Especially dark images are being misdecoded by darktable so they are whole ping-violet and therefore unusable. However, same issue was addresed for P7100 which has the same sensor so the fix can be easily ported.

Below is the patch that does the trick:

--8<----------------------------------------------------------------------------

--- /usr/share/darktable/rawspeed/cameras.xml.orig 2014-07-17 11:37:00.038371319 0200
+
+ /usr/share/darktable/rawspeed/cameras.xml 2014-07-17 11:24:05.718511678 0200
@ -1436,6 +1436,9 @
</CFA>
<Crop x="0" y="0" width="0" height="0"/>
<Sensor black="0" white="4095"/>
<Sensor black="250" white="4095" iso_min="400" iso_max="0"/>
+ <!-- In usual Nikon style, ISO 6400 is marked as ISO 0 -->
+ <Sensor black="260" white="4095" iso_min="0" iso_max="1"/>
<Hints>
<Hint name="coolpixmangled" value=""/>
</Hints>

---------------------------------------------------------------------------->8--

nikon_p7000.patch Magnifier (535 Bytes) Martin Kyral, 07/17/2014 03:29 PM

History

#1 Updated by Martin Kyral almost 5 years ago

OMG... %s/ping/pink/g please :)

#2 Updated by Martin Kyral almost 5 years ago

proposed patch

#3 Updated by Pascal de Bruijn over 4 years ago

  • % Done changed from 0 to 100
  • Target version changed from Candidate for next patch release to Candidate for next major release
  • Status changed from New to Fixed

Also available in: Atom PDF